• + 39 0775/392052 info@digitron-italia.it
  • versione inglese  versione tedesco  versione spagnolo

Modular, compact in-line flow meter for DN15 to DN50

Easily adapted for any measuring task

The HLX741 in-line flow meter can be easily adapted for any measuring task. It is dedicated for accurate metering and monitoring of compressed air and technical gases in DN 15 to DN50 pipes. 

The thermal measuring principle and the well proven hot film sensor element lead to best long-term stability and fast response time. 

Outstanding measuring accuracy, even in the lower measuring range, is achieved by an application-specific multi-point factory adjustment performed at 7 bar (102 psi). This allows reliable leak detection and corresponding energy savings. The construction of the HLX741 flow meter is optimised for easy installation and maintenance. 

Modular design 

One and the same transmitter can be used for each of thrHLX pipe diameters: 

  • HLX741: DN15 (1/2") / DN20 (3/4") / DN25 (1")

  • HLX741-N50: DN32 (1-1/4") / DN40 (1-1/2") / DN50 (2")

The pipe diameter is easily set via the display menu or the HLX-PCS product configuration software. 

Once the gauge mounting block is installed in the pipeline, the transmitter can be installed and removed without any pipework. As a result, the HLX741 flow meter is also ideal for temporary measurement at several installed mounting blocks. The sealing plug included in the scope of supply enable the normal operation of the compressed air system when the transmitter is removed. 

Display (optional) 

The state-of-the-art LCD shows the current measured values and the overall consumption. The HLX741 setup can be easily performed with the push buttons and intuitive menu guidance. The display can be rotated in 90° increments with a push button for convenient orientation in any mounting position of the flow meter. 

Key Features

  • Modular design
  • Removal without dissasembling the pipework
  • Application-specific adjustment under pressure
  • Exceptional price/performance ratio
  • Analogue, pluse and switching output
  • Modbus RTU and M-Bus
  • Integrated consumption meter

Typical Applications

  • Compressed air consumption measurement
  • Monitoring of technical gases O2, N2, Ar, CO2. Other gases upon request
  • Nitrogen generators
  • Leak detection

Technical data

  • MEASURED VALUES

    standardized volumetric flow, mass flow, standardised flow, temperature, consumption

  • PIPE DIAMETER

    DN15 / DN20 / DN25 
    DN32 / DN40 / DN50

  • MEASURING RANGE - FLOW

    DN15: 0.2 - 76.3 Nm³/h 
    DN20: 0.4 - 135.6 Nm³/h 
    DN25: 0.6 - 212 Nm³/h

  • MEASURING RANGE - FLOW

    DN32: 0.9 - 347.4 Nm³/h 
    DN40: 1.4 - 542.8 Nm³/h 
    DN50: 2.2 - 848.2 Nm³/h

  • ACCURACY - FLOW (MEASURED VALUE)

    ±(3 % of mv + 0.3% del fondo scala)

  • MEASURING RANGE - TEMPERATURE

    -20...60 °C (-4...140 °F)

  • ACCURACY - TEMPERATURE

    ± 0.7 °C (1.26 °F)

  • OUTPUTS

    0/4-20 mA, impulsi, switch, Modbus RTU o M-Bus

  • SUPPLY

    18 - 30 Vdc

Download Data Sheet Send Mail for information See Air Flow